Power Range |
Dæmigert forrit |
|
25–90kva |
Heimili, litlar verslanir, fjarskiptastöðvar |
|
100–250kva |
Bændur, heilsugæslustöðvar, skólar, litlar verksmiðjur |
|
300–500kva |
Mid - stærð iðnaðarstaði, byggingarbúðir |
Fáanlegt í opinni gerð, hljóðláta tjaldhiminn og kerru - festar stillingar.
Tæknilegar forskriftir (sýnishorn)
|
Fyrirmynd nr. |
Biðkraftur |
Aðal kraftur |
Vélarlíkan |
Spenna |
Tíðni |
Stillingar |
|
WF30 |
30kva |
27kva |
495D-15 |
230/400V |
50Hz |
Þögul / opið |
|
WF100 |
100kva |
90kva |
R6105AZLD |
230/400V |
50Hz |
Þögul / opið |
|
WF200 |
200kva |
180kva |
R6113AZLD |
230/400V |
50Hz |
Þögul / opið |
|
WF400 |
400kva |
360kva |
12V135AZLD |
230/400V |
50Hz |
Ílát |
|
WF500 |
500kva |
450kva |
TBD226B-6 |
230/400V |
50Hz |
Ílát |
Sérsniðin 60Hz, margfeldi spennu og ATS valkostir í boði.
95/100/105 serían Ricardo rafall sett er lóðrétt fjögurra strokka, sex strokka, vatn - kældur, fjögur högg, bein innspýting hátt - hrað rafall sett. Rafmagnið er 26,5-132kW, með hraða 1500-2400R/mín., Sem hefur kostina við litla eldsneytisnotkun, stórt tog, auðvelt byrjun og þægilegan rekstur og viðhald. Kjörinn kraftur fyrir rafallbúnað, fastan kraft, smíði vélar og landbúnaðarvélar.
Helstu breytur Ricardo Power Generator Set
|
Líkan |
metinn kraftur (KW/KVA) |
Biðmáttur (KW/KVA) |
Dísilvél |
rafall |
Ytri víddir (mm) |
Brúttóþyngd (kg) |
||
|
Líkan |
metið kraft (KW) |
Líkan |
metið kraft (KW/KVA) |
|||||
|
20GF |
20/25 |
22/27.5 |
K4100D |
30 |
PI144E |
20/25 |
1600x640x1000 |
680 |
|
24GF |
24/30 |
26.4/33 |
K4100D |
30 |
PI144G |
24/30 |
1600x640x1000 |
680 |
|
30GF |
30/37.5 |
33/41.25 |
K4100ZD |
42 |
PI144J |
30/37.5 |
1700x700x1100 |
790 |
|
30GF |
30/37.5 |
33/41.25 |
K4102D |
33 |
PI144J |
30/37.5 |
1700x700x1100 |
790 |
|
40GF |
40/50 |
44/55 |
K4100ZD |
42 |
UCI224D |
40/50 |
1870x720x1250 |
860 |
|
40GF |
40/50 |
44/55 |
N4105ZD |
56 |
UCI224D |
40/50 |
1870x720x1250 |
860 |
|
50gf |
50/62.5 |
55/68.75 |
R4105ZD |
56 |
UCI224E |
50/62.5 |
1870x720x1250 |
860 |
|
50gf |
50/62.5 |
55/68.75 |
N4105ZD |
56 |
UCI224E |
50/62.5 |
1870x720x1250 |
860 |
|
60gf |
60/75 |
66/82.5 |
R6105ZD |
84 |
UCI224F |
60/75 |
2210x720x1380 |
910 |
|
60gf |
60/75 |
66/82.5 |
R4105ZLD |
66 |
UCI224F |
60/75 |
2210x720x1380 |
910 |
|
60gf |
60/75 |
66/82.5 |
N4105ZLD |
66 |
UCI224F |
60/75 |
2210x720x1380 |
910 |
|
80gf |
80/100 |
88/110 |
R6105ZD |
84 |
UCI274C |
80/100 |
2210x720x1380 |
910 |
|
100GF |
100/125 |
110/137.5 |
R6105AZLD |
110 |
UCI274D |
100/125 |
2340x720x1550 |
1350 |
|
120GF |
120/150 |
132/165 |
R6105izld |
132 |
UCI274F |
120/150 |
2570x775x1725 |
1450 |
|
150GF |
150/187.5 |
165/206.25 |
R6113Zld |
155 |
UCI274G |
150/187.5 |
2570x775x1725 |
1650 |
|
150GF |
150/187.5 |
165/206.25 |
R6110ZLD |
170 |
UCI274G |
150/187.5 |
2570x775x1725 |
1650 |
|
160GF |
160/200 |
176/220 |
R6126ZLD204 |
204 |
UCI274H |
160/200 |
2950X1150X1700 |
2150 |
|
200gf |
200/250 |
220/275 |
R6126ZLD235 |
235 |
UCD274K |
200/250 |
2950X1150X1700 |
2150 |
|
250GF |
250/312.5 |
275/343.75 |
R6126ZLD288 |
288 |
HCI444ES |
250/312.5 |
3250x1250x1830 |
2350 |
Lykilatriði Weifang dísilrafala
- Affordable & endingargott- kostnaður - árangursríkar valdalausnir með langri þjónustulífi.
- Auðvelt viðhald- einföld uppbygging og víða tiltækir varir.
- Sveigjanleg forrit- Hentar fyrir dreifbýli, smíði, fjarskipta og litla - kvarða iðnaðarnotkun.
- Lítil eldsneytisnotkun- bjartsýni eldsneytiskerfi fyrir minni rekstrarkostnað.
- Ýmsar stillingar- Opið, þögul eða kerru - fest hönnun til að passa við mismunandi þarfir.

Kalla til aðgerða
Hafðu samband við Weifang Diesel rafall verðlagningu, forskriftir eða sérsniðnar stillingar.


maq per Qat: Weifang Generator Set, China Weifang Generator Set birgjar, verksmiðju